GYXTW 12 G652D Fiber Optic Ethernet Cable Uni - Tube PE Jacket
GYXTW is an outdoor use optical fiber cable suitable for duct and aerial applications. We supply GYXTW fiber optic cable from 2 fiber cores to 12 fiber cores. Both single mode type and multimode types are available.
GYXTW 12 G652D Fiber Optic Ethernet Cable Uni - Tube PE Jacket
Outdoor Aerial GYXTW 12 G652D Fiber Optic Armoured Cable OS2 Uni-tube PE Jacket ,HDPE
GYXTW is an outdoor use optical fiber cable suitable for duct and aerial applications. We supply GYXTW fiber optic cable from 2 fiber cores to 12 fiber cores. Both single mode type and multimode types are available.
Feature
· The fibers, 250μm, are positioned in a loose tube made of a high modulus plastic.
· The tubes are filled with a water-resistant filling compound.
· The tube is wrapped with a layer of corrugated steel tape longitudinally.
· Between the corrugated steel tape and the loose tube water-blocking material is applied to keep the cable compact and watertight.
· Two parallel steel wires are placed at the two sides of the steel tape.
· The cable is completed with PE sheath.
Application
Usable in Self-supporting
Fiber color coding
Each fiber will be identifiable throughout the length of the cable in accordance with the following color sequence. Fiber color in each tube starts from No. 1 Blue.
NO. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Fiber Color | Blue | Orange | Green | Brown | Slate | natural | Red | Black | Yellow | Violet | Pink | Aqua |
Fiber Parameter
No. | Items | Unit | Specification | |
G.652D | ||||
1 | Mode Field Diameter | 1310nm | μm | 9.2±0.4 |
1550nm | μm | 10.4±0.5 | ||
2 | Cladding Diameter | μm | 124.8±0.7 | |
3 | Cladding Non-Circularity | % | ≤0.7 | |
4 | Core-Cladding Concentricity Error | μm | ≤0.5 | |
5 | Coating Diameter | μm | 245±5 | |
6 | Coating Non-Circularity | % | ≤6.0 | |
7 | Cladding-Coating Concentricity Error | μm | ≤12.0 | |
8 | Cable Cutoff Wavelength | nm | λcc≤1260 | |
9 | Attenuation (max.) | 1310nm | dB/km | ≤0.36 |
1550nm | dB/km | ≤0.24 |
Cable Parameters
Items | Specifications | |
Fiber Count | 2~12 | |
Colored Coating Fiber | Dimension | 250µm±15µm |
Color | Blue, Orange, Green, Brown, Gray, White | |
Loose Tube | Dimension | 2.10mm±0.05mm |
Material | PBT | |
Color | Natural | |
Strength Member | Diameter | 1.0mm |
Material | Steel | |
Outer Jacket | Dimension | 8.0mm±0.1mm |
Material | PE | |
Color | Black |
Mechanical and Environmental Characteristics
Items | Unite | Specifications |
Tensio (Long Term) | N | 600 |
Tension (Short Term) | N | 1500 |
Crush (Long Term) | N/10cm | 300 |
Crush (Short Term) | N/10cm | 1000 |
Min. Bend Radius (Dynamic) | mm | 20D |
Min. Bend Radius (Static) | mm | 10D |
Installation Temperature | ℃ | -20~+60 |
Operating Temperature | ℃ | -40~+70 |
Storage Temperature | ℃ | -40~+70 |
Technical Parameter
Fiber Count | Cable Diameter (mm) | Cable Weight (kg/km) |
Tensile Strength Long/Short Term (N) |
Crush Resistance Long/Short Term (N/100mm) |
Bending Radius Static/Dynamic (mm) |
2~12 | 8.0 | 92 | 1000/3000 | 1000/3000 | 10D/20D |
Transmission Characteristics | |||||
G.652 | G.655 | 50/125μm | 62.5/125μm | ||
Max Attenuation (dB/km) (+20℃) |
850 nm | 3.0 | 3.3 | ||
1300 nm | 1.0 | 1.0 | |||
1310 nm | 0.36 | 0.4 | |||
1550 nm | 0.24 | 0.23 | |||
Cable Cute-off Wavelength (nm) | ≤1260 | ≤1450 |
Mechanical requirements and methods of fiber cable
Tensile strength | 2850N, conform to IEC 794-1-E1 while fiber strain is ≤0.33% |
Crush | 2200N/100mm, conform to IEC 794-1-E3 |
Impact | conform to IEC 794-1-E4 |
Repeated bending | conform to IEC 794-1-E6 |
Temperature cycling test | conform to IEC 794-1-F1 |