FIBEROPTIC

Conduit 7.0 8.0 Fiber Optic Armoured Cable For Outdoor GYTS 24 48B1.3

GYTS-24/48B1.3 Armored Fiber Optic Armoured Outdoor Cable G652D The Conduit 7.0 or 8.0

Conduit 7.0 8.0 Fiber Optic Armoured Cable For Outdoor GYTS 24 48B1.3

GYTS-24/48B1.3 Armored Fiber Optic Armoured Outdoor Cable G652D The Conduit 7.0 or 8.0

GYTS-24/48B1.3

Cable design

  • 12 SM-fibers (max.) placed in each tube.
  • Steel wire as central strength member.
  • Loose buffer tubes SZ-stranded.
  • The buffered tube filled with filling compound while the stranded core covered with water block material
  • Corrugated steel tape armored for rodent attack.
  • HDPE Cable Outer sheath.
  • Suitable as: Duct Installation.

 

1 Reference Standard

IEC 60793-1, 60793-2, 60794-1

ITU-T G650, G652

 

2 Optical and mechanical characteristics of fiber
MFD(1310nm) 9.2mm±0.4mm
MFD(1550nm) 10.4mm±0.8mm
Cladding diameter 125mm±1.0mm
Fiber diameter 250 ± 15 mm (Colored)
Core/cladding concentricity error £0.6mm
MFD concentricity error £0.8mm
Cladding non circularity £1.0%
Cut off wavelength £1260nm
Attenuation coefficient 1310nm: £0.35dB/km
1550nm: £0.21dB/km
Bending-loss performance of optical fiber £0.05dB
Polarization mode dispersion £0.1ps/Ökm
Zero-dispersion wavelength 1300 – 1324 nm
Zero-dispersion slope £0.092ps/(nm2•km)
3 Mechanical requirements and methods of fiber cable
Tensile strength 1500N, conform to IEC 60794-1-E1 while fiber strain is ≤0.33%
Crush 1000N/100mm, conform to IEC 60794-1-E3
Impact conform to IEC 60794-1-E4
Repeated bending conform to IEC 60794-1-E6
Torsion conform to IEC 60794-1-E7
Flexing conform to IEC 60794-1-E8
Kink conform to IEC 60794-1-E10
Cable bend conform to IEC 60794-1-E11
Temperature cycling test conform to IEC 60794-1-F1
Water penetration conform to IEC 60794-1-F5B
Spark test voltage Spark test voltage of cable outer jacket will be no less than 8kV AC
4 Fiber color coding and Tube color coding
Color code 1 2 3 4 5 6
Blue Orange Green Brown Slate White
7 8 9 10 11 12
Red Black Yellow Violet Rose Aqua
5 Structure

Conduit 7.0 8.0 Fiber Optic Armoured Cable For Outdoor Use G652D GYTS 24 48B1.3 0

 

 

 

6 Mechanical specification
Items Descriptions
Optical fiber Category G.652D
Counts 24 48
Optical fibers per tube Counts Max. 12
Central strength member Material Steel wire
Diameter(mm) 1.55
PE cushion(mm) 1.55
Loose tube Material PBT
Diameter(mm) 2.0
Counts 2 4
Filler rod Counts 3 1
Color Nature
Armor Material Corrugated steel tape
Outer sheath Material HDPE
Color Black
Thickness (mm) Nominal 1.7
Cable diameter (mm) ±0.5 9.7
Cable weight (kg/km) ±10% 101 105
Tensile strength Short term(N) 1500
Long term(N) 600
Crush Short term(N/10cm) 1000
Long term(N/10cm) 300
Applicable temperature range Operation – 40℃ ~ +70℃
Installation – 20℃ ~ +60℃
Storage & shipping – 40℃ ~ +70℃
Bending Radius unloaded 10 times of outer diameter
loaded 20 times of outer diameter