External Aerial Fiber Optic Armoured Cable GYTA 24B1.3
The 250μm fiber is positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. The tube is wrapped with a layer of PSP longitudinally. Between the PSP and the loose tube water-blocking material is applied to keep the cable compact and watertight. Two parallel steel wires are placed at the two sides of the steel tape. The parallel steel wires are placed at the two sides tape. The cable is completed with a polyethylene (PE) sheath.
External Aerial Fiber Optic Armoured Cable GYTA 24B1.3
External Aerial Fiber Optic Armoured Cable G652D GYTA 24B1.3 2km 4km Per Roll
GYTA-24B1.3
Description
The 250μm fiber is positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. The tube is wrapped with a layer of PSP longitudinally. Between the PSP and the loose tube water-blocking material is applied to keep the cable compact and watertight. Two parallel steel wires are placed at the two sides of the steel tape. The parallel steel wires are placed at the two sides tape. The cable is completed with a polyethylene (PE) sheath.
Features
Good mechanical and temperature performance
High strength loose tube that is hydrolysis resistant
Special tube filling compound ensure a critical protection of fiber
Crush resistance and flexibility
PSP enhancing moisture-proof
Two parallel steel wires ensure tensile strength
Small diameter, light weight and friendly installation
Storage / Operating Temperature: -40℃~+70℃
Application
Usable in Duct / Aerial
Cable design
- 24 SM-fibers.
- Steel wire as central strength member.
- Loose buffer tubes SZ-stranded.
- The buffered tube filled with filling compound while the stranded core covered with aluminum tape
- PE Cable outer sheath
- Suitable as: duct installation
Reference Standard
IEC 60793-1, 60793-2, 60794-1
ITU-T G650, G652
Optical and mechanical characteristics of fiber
MFD(1310nm) | 9.2mm±0.4mm |
MFD(1550nm) | 10.4mm±0.8mm |
Cladding diameter | 125mm±1mm |
Fiber diameter | 250 ± 15 mm (Colored) |
Core/cladding concentricity error | £0.6mm |
Cladding non circularity | £1.0% |
Cut off wavelength | £1260nm |
Attenuation coefficient | 1310nm: £0.36dB/km |
1550nm: £0.22dB/km | |
Bending-loss performance of optical fiber | £0.05dB |
Polarization mode dispersion | £0.1ps/Ökm |
Zero-dispersion wavelength | 1300 – 1324 nm |
Zero-dispersion slope | £0.093ps/(nm2•km) |
Mechanical requirements and methods of fiber cable
Tensile strength | 1500N, conform to IEC 794-1-E1 while fiber strain ≤0.33% |
Crush | 1000N/100mm, conform to IEC 794-1-E3 |
Impact | conform to IEC 794-1-E4 |
Repeated bending | conform to IEC 794-1-E6 |
Torsion | conform to IEC 794-1-E7 |
Flexing | conform to IEC 794-1-E8 |
Kink | conform to IEC 794-1-E10 |
Cable bend | conform to IEC 794-1-E11 |
Vibration | conform to IEC 794-1 |
Water penetration | conform to IEC 794-1-F5B |
The dielectric strength of outer jacket | conform to ITU-T Rec.K25 |
Spark test voltage | Spark test voltage of cable outer jacket will be no less than 8kV AC |
Abrasion | conform to IEC 794-1-E2 |
Temperature cycling test | conform to IEC 794-1-F1 |
Fiber color coding
Loose tube color code | 1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Slate | White | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Violet | Rose | Aqua |
Tube color coding
Loose tube color code | 1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Slate | White | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Violet | Rose | Aqua |
Structure
Mechanical specification
Items | Descriptions | |
Optical fiber | G.652 | |
Central strength member | Material | Steel wire |
Diameter(mm) | 1.45 | |
Loose tube | Material | PBT |
Outer sheath
|
Material | PE |
Thickness(mm) | 1.6 | |
Cable diameter(mm) | 8.9 | |
Cable weight(Kg/km) | 75 | |
Tensile strength | Short term(N) | 1500 |
Long term(N) | 600 | |
Crush | Short term(N/10cm) | 1000 |
Long term(N/10cm) | 300 | |
Applicable temperature range | Operation | – 40℃ ~ +70℃ |
Installation | – 40℃ ~ +70℃ | |
Bending Radius |
Storage & shipping | – 40℃ ~ +70℃ |
unloaded | 10 times of outer diameter | |
loaded | 20 times of outer diameter |